Follow these before Choosing a Colocation facility

In the jet age communication and data access areControl on Climate
two most important factors for business operations.Design of the colocation facility itself affects the
Email, messaging websites and servers have to be upperformance of the systems used in the colocation
24x7 and they should be protected for businessfacility. Air flow between rack rows should be
communication to function. Specially Data Centerscontrolled by the server rooms. Hot air generated
which have servers with mission critical information.due to the heat produced by the servers should be
Most important are company databases and servers,blown in one direction and cool air to keep the
which should be kept up at any cost. Importantservers cool should exit from another direction. Only
factors in a colocation facility are: Equal Distribution ofdedicated hot and cols air flow can save the servers
Trafficfrom overheating and finally burning down. Cold sir
Both hardware and logic of distribution has anand humidity is controlled by correctly sized and
important effect on connectivity. The way traffic isredundant climate control units. As we all know
divided plays an important role in the performance ofclimate requirements for the server are strict and
routing. If your distribution covers three below giventhey only work properly when they are installed
points than it is perfect:under suitable working environment. Servers need
- Switches and routers should be redundant and be50% humidity and 70 degrees of temperature. Both
working on full working for the customers.CRAC units and chillers for the server rooms should
- Distributions should be done between more thanbe included in a Colocation facility. Cooling capacity is
4-5 clients.calculated by total tonnage by the square footage.
- In order to continually adjusting routes to find thePower Required
most effective one Performance based distribution isPower to the colocation is like oxygen to the
should be used. Performance based concentrates onhumans, if it fails to perform then you are in deep
performance rather then price.trouble. UPS and generators should be used for
Best Connectivitybackup and they are necessary to keep the network
Major points which decides the Internet Connectivityonline. UPS are used when power is shifted from
of a colocation facility are as follows:regular to the generators. Generators should be there
- Accessible Internet backbones24X7 for immediate backup power. Power system of
- Packet loss, jitter and Latencya colocation facility should be properly working and
- Uptime guaranteeshould have following features for perfection:
- Total Bandwidth available for usage Carrier-neutral- Generator which can handle at least 1.5 time the
access and Tier -1 carriers, tier-2 carriers all gettotal building load
access to internet using Colocation data centers.- Redundant and multiple UPS because of the reason
Carrier-neutral can be used by any service from anyUPS fails very oftenly.
carrier but customers are requested to configure
their own routing. Also customers are should maintainRedundant Systems
their own connections to Internet backbones. Tier-1Systems used in colocation hosting should be
is used by Internet giants like AT&T for directredundant and at every point of working they should
access. Tier-2 is used for routing traffic amongst thehave proper capacity. Many people get confused with
multiple Tier-1 providers. In these kind of tiers speedmultiple units considering them as redundancy. Ideal
and reliability depends on how effectively traffic isconfiguration for systems used in colocation facilities
routed. Tier-2 is preferred by most of the clientsshould be n+1, which means that if there are two
since routing is configured by the Colocation facility.units they should run at 50% capacity, and in any
Also it is more reliable because of the presence ofcase if one fails other will handle the load. Same if
backbones, these backbones network performancethere are three units working capacity should be
and uptime.66%.