How Data Recovery Is Performed On Failed Raid 5 Arrays

How Data Recovery is Performed on Failed RAID 5corrupt or missing causing an entire partition to
Arraysdisappear or become unusable. This makes data
RAID 5 arrays are used for many applicationsrecovery necessary. Attempting recovery with
because they are for the most part cost-effectivesoftware will increase the risk of permanent data
and provide a level of fault tolerance not provided byloss.
some other levels of RAID. Visit hereRAID 5 Controller Failure
As with any RAID level, RAID 5 can experienceA Hardware RAID 5 array uses a controller which
many different types of problems. This article willcontains all of the logic and handles the operations of
provide a brief discussion of some of the problemsthe array. For many reasons, the array can
causing RAID 5 failure and how data recovery canexperience a controller failure. This can cause the
work to solve these problems.array to not boot. It could also cause the logical
Problems That Can Cause RAID 5 Failurevolume to disappear.
Bad SectorsRAID 5 Disk Failure/RAID 5 Drive Failure
A RAID 5 can fail due to bad sectors on any of theA RAID 5 is a set of three or more disk drives. Any
disks in the array. This can force the array to goof these drives can experience failure. A RAID 5 is
offline.configured with the ability to withstand the failure of
Corrupt Dataonly one disk at a time. In most cases, the RAID can
A RAID 5 can suffer from corrupt data due to manybe recovered in a data recovery lab using parity data
reasons including viruses, user error, overwriting files,written to the disks by the array. Even if more than
and scratches on the surface of the disk platters.one disk has failed, data recovery is still possible in a
Degraded RAID 5recovery lab.
A RAID 5 becomes degraded when there is a loss ofRAID 5 Firmware Failure
one of the member disks. This causes a hugeFirmware problems can occur in the RAID controller
decrease in performance and also removes the faultor the member disk drives.
tolerance of the RAID 5. Operating a degraded RAIDRAID 5 Rebuild Failure
5 is dangerous because the loss of a second disk willFor various reasons, a RAID 5 array can experience a
cause the entire array to be lost.rebuild failure. This may keep member disks offline
Deleted Filesand render the array unusable.
Many times a user will accidentally delete importantServer Crash
data in a RAID 5 array. Other times, it is doneMany times, the host server experiences problems
intentionally by disgruntled employees. In mostand can crash. This of course makes the array
situations, deleted files can be recovered.unaccessible. A data recovery lab can recover the
Missing Partitionsdata from the member disks.
In many cases, the partition table can become