Ups Applications And Selecting Uninterruptible Power Supplies

Uninterruptible Power Supplies (UPS) or UPS SystemsEnvironments
as they are also known provide two importantUninterruptible power supplies sized 3-15kVA typically
power solutions roles. UPS systems provide a sourcepower larger ICT installations including server and
of standby back-up power when the mains powercomms rooms, Blade servers, virtual PABx and file
supply fails, and they also provide conditioning toservers. UPS systems within this range include floor,
remove mains borne power problems – sags,rackmount and combo formats, with a single-phase
surges, brownouts, spikes and electrical noise. Poweroutput and options for three-phase inputs. Models up
problems can lead to IT system hardware failure,to 3kVA will generally plug in using industrial 16A
system malfunctions and corrupt data. In today’scommando sockets, with larger models requiring
24/7 business continuity conscious world, demand forelectrical installation by a suitably qualified electrical
UPS systems continues to grow at an exponentialengineer (working to the latest IEE Regulations), and
rate.then commissioning by a certified engineer.
There are off course different types of UPSUPS for this type of application include off-line, line
topology and these include on-line double-conversioninteractive and on-line designs up to 3kVA. On-line
UPS, line interactive UPS and Standby or Off-line UPS.uninterruptible power supplies in this range are
Selection is often based upon price budgettransformerless so as to achieve a small footprint,
considerations and the level of availability andminimal weight and low noise and heat output. They
resilience required. However it can also be useful toare usually located in computer rooms, next to
consider UPS selection by the application environmentprotected equipment. However, their reduced size
the UPS system will find itself within.means fewer output sockets, so in highly populated
PC UPS: small Office Home Office (SoHo) ICTenvironments a greater number may be required,
Environmentswhich will have an impact on capital and operating
Information and Communications Technology (ICT)costs.
environments typically include PCs, POS Terminals andDatacentre UPS: large-sized ICT Environments
small File Servers and run from 300VA-800VA. TheseLarge UPS systems run from 20-800kVA and
are ‘fit and forget’ UPS systems with atypically form the backbone of large power solutions
small internal battery pack. They will provideprojects protecting applications such as datacenters
protection from sags, surges, brownouts, spikes andand telecoms switching centres. These uninterruptible
electrical noise and a short duration runtime on mainspower supplies tend to be installed as part of a
power failure. Typical applications include: PCs,centralised or decentralised power protection plan,
workstations, small file servers, Electronic Point ofoffering N+1 parallel modules for extra resilience and
Sale (EPoS) terminals, Small Office and Home Officea full turn-key package including electrical installation
(SoHo) systems, Hi-Fis, satellite systems, routers,and ongoing remote monitoring and maintenance
modems and switches. The UPS systems will be lineplans.
interactive UPS or standby UPS.Industrial UPS Systems
Network UPS: small-sized ICT EnvironmentsOn-line uninterruptible power supplies are typically
UPS systems in this size range (1-2kVA) will beavailable in transformer-based and transformerless
powering network applications including file servers,designs. The transformer-based are ideal for use
telecoms switches, network servers, Blade servers,within industrial applications because of their more
PABX, PoE, VOIP and PABX telecoms systems.rhobust design; a transformer performs the essential
These UPS will be on-line double conversion systemsmains conditioning role in place of electronics. Larger
or line interactive UPS with some offering options forthree-phase UPS systems may also provide a number
additional battery runtime packs. Formats include:of other electrical specification options including
tower UPS, floor standing UPS, rackmount UPS and6-pulse or 12-pulse rectifiers, and even IGBT
combo UPS capable of either tower or 19"(Integrated Gate Bipolar Transistor) based rectifiers
rackmount installation.to provide very high input efficiencies and low Total
Comms and Server Room UPS: medium-sized ICTHarmonic Distortion (THDi) inputs.